Semiconductor Cleanroom Cleaning

Fab and electronics cleanrooms, gowning rooms, clean corridors, service chases and the offices around them, cleaned in the gowning order, wipe-down sequence and agents your facility’s protocol sets.

Request a quoteCall (209) 762-8986

Cleanroom cleaning that runs on your protocol

Denali cleans semiconductor fabs, electronics assembly areas and nanofabrication suites, along with the locker rooms, gowning rooms, corridors, service chases and offices around them. Inside the cleanroom, every step comes from your facility’s written protocol and your cleanroom manager: the gowning order, the agent, the wipes, the wipe-down sequence and the log.

People are the main particle source in a cleanroom, so the crew’s discipline matters as much as its tools. This page is for cleanroom, facility and EHS managers at fabs and electronics plants. Research and quality labs without classified space are covered by our laboratory facility cleaning.

Chipmaking in California

California had over 600 fabrication facilities, more than any other state, and about 63,000 semiconductor-supported jobs, per the Governor’s Office of Business and Economic Development in June 2023. In November 2024 the Governor’s office announced that the National Semiconductor Technology Center’s headquarters would be in Sunnyvale.

Around Denali’s East Bay cities, Fremont, Livermore, Hayward and San Leandro, electronics and technical manufacturing sit beside warehouses and research buildings. We also serve cleanroom buildings around Rancho Cordova and Reno.

What an ISO class measures

ISO 14644-1:2015 classifies a cleanroom’s air by the concentration of airborne particles, counted with light-scattering particle counters at set sampling points, for particle sizes from 0.1 to 5 micrometres. The class describes the air in your room, and your facility classifies and tests it. ISO 14644-5:2025 covers the operations program that keeps a room within its levels, including cleaning, gowning and training, but it leaves out cleaning-agent compatibility and industry-specific rules. That is why the agents and methods come from your facility and its suppliers.

The old class names are still in use. FDA’s 2004 aseptic processing guidance, written for pharmaceutical work, shows how they line up with ISO classes, counting particles of 0.5 micrometre and larger:

Old class nameISO classParticles per cubic metre (0.5 µm and larger)
Class 100ISO 53,520
Class 1,000ISO 635,200
Class 10,000ISO 7352,000
Class 100,000ISO 83,520,000

The old name is the particle count per cubic foot. By our estimate from those figures, 3,520 particles per cubic metre divided by about 35.3 cubic feet per cubic metre comes to about 100 per cubic foot, which is why ISO 5 and Class 100 match.

Rooms in and around a cleanroom

AreaTypical cleaningMethod set by
Locker room and pre-gowning areaFloors, benches, lockers and trash, with nothing left overnightYour entry rules
Gowning roomBenches, walls and floors cleaned from the clean side toward the dirty sideYour gowning protocol
Cleanroom baysCeilings, walls, windows, tables and equipment surfaces you name, then floorsYour cleanroom manager
Clean corridors and service chasesFloors and accessible surfaces on their own cycleYour protocol for that class
Offices, break rooms and restroomsRoutine janitorial care with ordinary productsThe building task list

Tools stay dedicated to the cleanroom, carts are kept free of debris, and nothing banned by your protocol, such as regular paper, cardboard or paper towels, comes through the gowning room with the crew.

Gowning and entry, by your posted sequence

Published fab protocols show how strict entry can be. For example, NIST’s NanoFab safety manual has staff pre-gown in the locker room with safety glasses, shoe covers, a hair net, a face mask and gloves, which is enough for its Class 1,000 areas and service chases but not for its Class 100 lab. Final gowning goes on from the top down, and no part of the gown may drag on the floor.

Another published protocol, from NY CREATES, starts at a shoe-brush vacuum and a tacky mat, moves through sanitized gloves, hairnet and shoe covers put on from the dirty side to the clean side, and ends with a jumpsuit, hood and an attire check. That protocol also requires garments to be changed completely at least once a week and gloves, booties and hairnets to be thrown away on exit. Denali crews gown exactly to the sequence your facility posts, train on it before the first entry and keep trips in and out to a minimum.

Wipe-down order and the cleaning log

The NY CREATES protocol is a useful example of a full wipe-down. Cleanroom staff work under the cleanroom manager at a set frequency, using 10% IPA and 90% DI water. Cleaning starts in the cleanest area, usually the point farthest from the main pass-through, and works toward the pass-through and exit. Each area is wiped from the ceiling down, then walls and windows, then equipment and tables, and the floor comes last. Every wipe-down is logged, and problems go to the cleanroom manager.

Your own protocol may set a different agent, order or frequency, and Denali follows it as written. Crews log each wipe-down in your format, report anything out of place to the person you name, and leave tools and process equipment to your technicians.

Static control in electronics areas

Electrostatic discharge can destroy a part outright or damage it in ways that only show up as an early failure. The ESD Association’s figures show that walking across vinyl tile can build about 12,000 volts at 10 to 25 percent relative humidity. ANSI/ESD S20.20 sets the requirements for an ESD control program, and any area where ESD-sensitive items are handled is an ESD protected area.

Static-control floors ground people through a floor and footwear system. S20.20 sets two limits for that system: resistance through the person, footwear and floor under 1.0 x 10^9 ohms, and body voltage in a walking test under 100 volts. A conductive floor measures 1.0 x 10^6 ohms or less to ground, and a dissipative floor falls between that and 1.0 x 10^9 ohms. The floor maker’s instructions and your ESD program decide what goes on those floors, and Denali’s industrial floor care uses only the products and methods they name. Carts and machines brought into a protected area meet your rules for wheels and casters.

One schedule for the whole building

Cleanroom wipe-downs run at the frequency your manager sets and can be timed for planned tool downtime. Gowning rooms and corridors follow their own cycle, and offices, break rooms and restrooms get evening service through our industrial office cleaning. Production floors outside the classified space can follow our manufacturing facility cleaning, and server rooms on the same campus can join through data center facility cleaning.

One supervisor covers every area and one report shows what was done in each, so the cleanroom log and the building’s janitorial record stay in step.

Request a cleanroom cleaning quote

Send us your cleanroom areas and classes, the gowning and entry protocol, the agents and wipes you supply and the hours each space is free, and Denali will return a quote built on them. Every crew member is background-checked, a supervisor inspects each area, and a certificate of insurance comes with the plan. Request a quote to start.

A few useful answers

Common questions

Who sets the ISO class of our cleanroom?

Your facility does. An ISO 14644-1 class describes the airborne particle count your team classifies and tests, and Denali cleans to your protocol for that room.

Will your crews use our cleaning agent and wipes?

Yes. Inside the cleanroom, crews use only the agents, wipes and tools your protocol names, in the order it sets.

Can cleaners follow our gowning sequence exactly?

Yes. Crews train on your posted gowning and entry sequence before the first entry and follow it on every visit.

Can Denali clean static-control floors?

Yes, using only the products and methods the floor maker and your ESD program specify for that floor.

Can service chases and the sub-fab run on a separate cycle?

Yes. Each class of space gets its own frequency, so chases, corridors and bays are cleaned on the schedule your manager sets.